JK (jkhiser) demonstrated this in his Numeric Input Keypads layout. StreamByter turns the panel on when you tap a button, then turns it off after a delay. I checked JK’s layout and the app source.
Before editing, use Share to email yourself a backup and work in a copy.
1. Add a momentary button called Panel Timer. Give it this Sysex message: F0 00 01 7E 77 75 01 V F7. In the panel’s General → Button Shows/Hides setting, select Panel Timer.
2. Add a momentary button called Show Settings to trigger it. Give that button F0 00 01 7E 76 75 01 V F7. For both buttons, use a one-byte V, no checksum, MIDI Off/On 0/127, display range 0–127, 2 ticks, and Display Zero off. Leave MIDI receive enabled on Panel Timer.
3. Add and install this in StreamByter Output Rules:
IF M00 == F0 00 01 7E 76 75 01
IF M07 == 7F
SND F0 00 01 7E 77 75 01 7F F7
SND F0 00 01 7E 77 75 01 00 F7 +D2000
END
BLOCK
END(MIDI Designer routes Sysex starting with F0 00 01 7E 77 back into the layout, where Panel Timer receives it.)
In Play Mode, tap the trigger once. The panel should open right away and close two seconds later. JK’s Numeric Input Keypads layout